Load Test Report
Specimen details - concrete cylinders wrapped with 2 layers of 6oo gsm unidirectional carbon fibre fabric by saturating fabric with epoxy adhesive.
Loading devise - 1000kN UTM
Test Method - AMTS 04-06-01
Location - Brisbane Laboratory
Specimen 1 - unwrapped concrete cylinder failure at 26.2 tonns
Specimen 2 - wrapped concrete cylinder failure at 85.5 tonns
Specimen 3 - wrapped concrete cylinder NO failure at maximum load 101.9 tons
Specimen 4 - wrapped concrete cylinder NO failure at maximum load 101.9 tons